1 2 3 | ||
Editor: damberger
Time: 2017/04/28 20:50:15 GMT+2 |
||
Note: changed folded spectrum example to 13C resolved NOESY-HSQC |
changed: - CARA does not use a folding/attribute. It only works with the real chemical shift. E.g. although a 3D 15N NOESY may be folded in the 15N dimension, the strips are found by navigating in an unfolded 15N-HSQC. In case the chemical shift is outside of the 15N sweep width of the 3D, the peak is still placed in the real position in the 2D. I.e. you must go outside the range of frequencies defined by the sweep width of the 3D to see the peak position. If the *show folded* option is selected you will also see the intensity from the folded resonance at the real position. CARA does not use a folding/attribute. It only works with the real chemical shift. E.g. although a 3D 13C NOESY may be folded in the 13C dimension, the strips are found by navigating in an unfolded 13C-HSQC. In case the chemical shift is outside of the 13C sweep width of the 3D, the peak is still placed in the real position in the 2D. I.e. you must go outside the range of frequencies defined by the sweep width of the 3D to see the peak position. If the *show folded* option is selected you will also see the intensity from the folded resonance at the real position.
Folding resp. Aliasing occurs when the spectral sweep width is smaller than the range of resonance frequencies in the spectrum. Spins outside of the sweep width are either folded into the spectrum (top->top) or aliased (top->bottom), depending on the experiment's method of frequency discrimination (TPPI vs. STATES respectively).
In XEASY, this was taken into account by attributing a folding/aliasing attribute x
to each peak. This is an integer number (most often -1,0 or 1). The observed chemical shift c
is then translated into the real shift by calculating c=c+x*sw
. Not setting x
(or setting it wrongly) for a certain number of peaks is a very common cause of errors in chemical shift lists generated for a structure calculation.
CARA does not use a folding/attribute. It only works with the real chemical shift. E.g. although a 3D 13C NOESY may be folded in the 13C dimension, the strips are found by navigating in an unfolded 13C-HSQC. In case the chemical shift is outside of the 13C sweep width of the 3D, the peak is still placed in the real position in the 2D. I.e. you must go outside the range of frequencies defined by the sweep width of the 3D to see the peak position. If the show folded option is selected you will also see the intensity from the folded resonance at the real position.
Be aware that CARA needs to know the folding type of the spectrum (RSH, States-TPPI, ...). uxnmr2xeasy produces XEASY .param files, which set this attribute to NO. You will need to change this entry using a Text-editor to RSH or States-TPPI depending on the experiment.
The arrow points to a group of aliased peaks (they have opposite sign to the other signals).
BACK: GlobalSettings
NEXT: GlobalCursor